Swift Marine Tech Services Pte Ltd. (SMTSSG) is an authorized sales and service partner of Honeywell in INDIA
“Your trusted partner for all HERMetic brands UTI Tapes Calibration & Services at Singapore & Indian Ports”
Best Rates guaranteed for Genuine Honeywell HERMetic UTI Products with factory warranty of 3 years

OUR UNITS ARE:
- GENUINE & TESTED (BRAND NEW) – SUPPORTED BY TESTING VIDEO.
- 100 % RELIABLE // TRUSTWORTHY – WITH WARRANTY/CALIBRATION CERTIFICATE OF 1 YEAR.
- OFFERED AT BEST MARKET RATES PRICE
WE ARE ALSO OFFERING BELOW SERVICES:
- SPARES SUPPLY – FOR ALL KIND OF UTI TAPES.
- REPAIRING FACILITY – SINGAPORE & INDIAN PORTS – CALIBRATION & SUPPLY WITHIN 24 HOURS GUARANTEED.
AVAILABLE MAKES WITH MODELS:-
HERMETIC: GT3 CHEM, GTEX, RTEX, MK3-LBI UNI, SAMPLER
Honeywell Marine Products
HERMetic Accessories for Marine Applications
What Is It?
The accessories include:
- HERMetic DIP 2: A 500-mm long graduated DIP rod, designed for easy penetration of sediments on tank bottom. It is attached to a 30-m long stainless steel tape.
- HERMetic DIP 2 GT: This is a closed, gas tight version of HERMetic DIP 2.
- HERMetic OXY: As per IMO requirement for Tanker Safety and Pollution Prevention, oxygen level needs to be determined before starting crude oil washing. The HERMetic OXY samples inert gas (or any other gas) over full tank height while preventing any gas release into the atmosphere.
- HERMetic Press: Provides reliable reading within the range of 1500-mm vacuum and 2500-mm pressure water column.
- Adaptors for MMC & Tanktech Valves: Storage tube and adaptors for HERMetic equipment (gauges and samplers) enable connection on existing non-Honeywell valves onboard.
How Does It Work?
What Problems Does It Solve?
The HERMetic range of accessories is essential to operations and helps users comply with the IMO requirements on Tanker Safety and Pollution Prevention 1978- Resolution A.446 (XI).
HERMetic UTImeter Gtex for Closed Operation

What Is It?
- Ullage level measurement
- Temperature verification
- Oil-water interface level detection
- HERMetic UTImeter Gtex with 1-inch sensing probe, FKM gaskets for key hydrocarbon applications
- HERMetic UTImeter Gtex Chem with 1-inch sensing probe, FFKM gaskets and tape connector for use with corrosive liquids
- HERMetic UTImeter Gtex Visc or HERMetic UTImeter Gtex Chem Visc with 2-inch load on the sensing probe, recommended for high viscous products in hydrocarbons or corrosive liquids.
How Does It Work?
The sensor of HERMetic UTImeter Gtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element, with its characteristics stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.
The unit complies with a host of regulations, including:
- IMO (Solas 74, MARPOL 73/78)
- ISO (4512, 3170, 4268)
- API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11)
- IP (PMM Part III-1, PMM Part IV)
- EC Directive 89/336/EEC (EMC)
- EC Directive 94/9/EC (MED)
- EC Directive 96/98/EC (ATEX 100a).
It has been approved by:
- National authorities (USCG, MSA, GOST-R)
- All major classification societies
- ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.
What Problems Does It Solve?
HERMetic UTImeter Rtex for Restricted Operation

What Is It?
The sensor of HERMetic UTImeter Rtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element and its characteristics are stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.
The unit complies with a host of regulations, including:
- IMO (Solas 74, MARPOL 73/78)
- ISO (4512, 3170, 4268)
- API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11 )
- IP (PMM Part III-1, PMM Part IV)
- EC Directive 89/336/EEC (EMC)
- EC Directive 94/9/EC (MED)
- EC Directive 96/98/EC (ATEX 100a).
It has been approved by:
- National authorities (USCG, MSA, GOST-R)
- All major classification societies
- ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.
How Does It Work?
The sensor of HERMetic UTImeter Gtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element, with its characteristics stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.
The unit complies with a host of regulations, including:
- IMO (Solas 74, MARPOL 73/78)
- ISO (4512, 3170, 4268)
- API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11)
- IP (PMM Part III-1, PMM Part IV)
- EC Directive 89/336/EEC (EMC)
- EC Directive 94/9/EC (MED)
- EC Directive 96/98/EC (ATEX 100a).
It has been approved by:
- National authorities (USCG, MSA, GOST-R)
- All major classification societies
- ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.