UTI TAPES

HOME / SERVICES / UTI TAPES

Swift Marine Tech Services Pte Ltd. (SMTSSG) is an authorized sales and service partner of Honeywell in INDIA

“Your trusted partner for all HERMetic brands UTI Tapes Calibration & Services at Singapore & Indian Ports”

Best Rates guaranteed for Genuine Honeywell HERMetic UTI Products with factory warranty of 3 years

Ullage-Temperature-Interface (UTI) oil/water detector is provided for rapid and accurate determination of the oil/water interface in storage tanks. UTI detectors also advise the user of various temperatures of the monitored liquid/gas. We provide four-range temperature testing, oil/water interface testing, calibration, repairs and replacement of inoperative parts. In most cases, same day turn-around of units is provided. We take this opportunity to introduce our-self as leading supplier of genuine uti tapes (ullage temperature interface tapes) of honeywell hermetic etc brands. Standing as reliable source to procure uti tapes for ships coming to indian ports and supplying reliable trustworthy units worldwide. We have brand new working units in ready stock in our testing laboratory for delivery to any ports at short notice.

OUR UNITS ARE:

  • GENUINE & TESTED (BRAND NEW) – SUPPORTED BY TESTING VIDEO.
  • 100 % RELIABLE // TRUSTWORTHY – WITH WARRANTY/CALIBRATION CERTIFICATE OF 1 YEAR.
  • OFFERED AT BEST MARKET RATES PRICE 

WE ARE ALSO OFFERING BELOW SERVICES:

  • SPARES SUPPLY – FOR ALL KIND OF UTI TAPES.
  • REPAIRING FACILITY – SINGAPORE & INDIAN PORTS – CALIBRATION & SUPPLY WITHIN 24 HOURS GUARANTEED. 

AVAILABLE MAKES WITH MODELS:-

HERMETIC: GT3 CHEM, GTEX, RTEX, MK3-LBI UNI, SAMPLER

Honeywell Marine Products

HERMetic Accessories for Marine Applications

Honeywell’s HERMetic range of marine accessories includes portable hand dipping, gas sampling and gas pressure measurement instruments for connection on all HERMetic compact valves.

What Is It?

The accessories include:

  •  HERMetic DIP 2: A 500-mm long graduated DIP rod, designed for easy penetration of sediments on tank bottom. It is attached to a 30-m long stainless steel tape.
  • HERMetic DIP 2 GT: This is a closed, gas tight version of HERMetic DIP 2.
  • HERMetic OXY: As per IMO requirement for Tanker Safety and Pollution Prevention, oxygen level needs to be determined before starting crude oil washing. The HERMetic OXY samples inert gas (or any other gas) over full tank height while preventing any gas release into the atmosphere.
  • HERMetic Press: Provides reliable reading within the range of 1500-mm vacuum and 2500-mm pressure water column.
  • Adaptors for MMC & Tanktech Valves: Storage tube and adaptors for HERMetic equipment (gauges and samplers) enable connection on existing non-Honeywell valves onboard.

How Does It Work?

All HERMetic accessories can be easily connected to HERMetic compact valves through a 1-inch quick connect coupling. In addition, Honeywell provides adaptors to connect the units to existing foreign valves onboard.

What Problems Does It Solve?

The HERMetic range of accessories is essential to operations and helps users comply with the IMO requirements on Tanker Safety and Pollution Prevention 1978- Resolution A.446 (XI).

HERMetic UTImeter Gtex for Closed Operation

​Honeywell Tanksystem’s HERMetic UTImeter Gtex is a portable gas tight liquid level gauge designed for closed gauging of hydrocarbons and chemicals. It ensures increased safety and efficiency in cargo control measurement, custody transfer, temperature verification and free water detection on marine vessels.

What Is It?

HERMetic UTImeter Gtex enables three measurements in a single operation:
  • Ullage level measurement
  • Temperature verification
  • Oil-water interface level detection
It is available in four versions:
  • HERMetic UTImeter Gtex with 1-inch sensing probe, FKM gaskets for key hydrocarbon applications
  • HERMetic UTImeter Gtex Chem with 1-inch sensing probe, FFKM gaskets and tape connector for use with corrosive liquids
  • HERMetic UTImeter Gtex Visc or HERMetic UTImeter Gtex Chem Visc with 2-inch load on the sensing probe, recommended for high viscous products in hydrocarbons or corrosive liquids.
HERMetic UTImeter Gtex allows easy battery exchange and can be fitted with interchangeable adaptors for connection on different vapor control valves. The tape cleaning devices, window wiper and tape protection are standard parts.

How Does It Work?

The sensor of HERMetic UTImeter Gtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element, with its characteristics stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.

The unit complies with a host of regulations, including:

  • IMO (Solas 74, MARPOL 73/78)
  • ISO (4512, 3170, 4268)
  • API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11)
  • IP (PMM Part III-1, PMM Part IV)
  • EC Directive 89/336/EEC (EMC)
  • EC Directive 94/9/EC (MED)
  • EC Directive 96/98/EC (ATEX 100a).

It has been approved by:

  • National authorities (USCG, MSA, GOST-R)
  • All major classification societies
  • ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.

What Problems Does It Solve?

​Honeywell’s HERMetic UTImeter Gtex allows static verification of the liquid level in a tank and continuous temperature reading of the liquid with high repeatability, thanks to the electronic detection principle. The fully modular unit ensures accuracy and stability, while reducing maintenance costs for users.

HERMetic UTImeter Rtex for Restricted Operation

​Honeywell’s HERMetic UTImeter Rtex is a portable electronic liquid level gauge designed for gauging of petroleum products under restricted conditions. A restricted system exists when a marine tank vessel allows some vapors from its cargo tanks into the atmosphere under normal operating conditions.

What Is It?

The sensor of HERMetic UTImeter Rtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element and its characteristics are stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.

The unit complies with a host of regulations, including:

  • IMO (Solas 74, MARPOL 73/78)
  • ISO (4512, 3170, 4268)
  • API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11 )
  • IP (PMM Part III-1, PMM Part IV)
  • EC Directive 89/336/EEC (EMC)
  • EC Directive 94/9/EC (MED)
  • EC Directive 96/98/EC (ATEX 100a).

It has been approved by:

  • National authorities (USCG, MSA, GOST-R)
  • All major classification societies
  • ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.

How Does It Work?

The sensor of HERMetic UTImeter Gtex is calibrated once at the factory and does not require subsequent calibration. The temperature probe is an RTD element, with its characteristics stored inside the sensor. The sensor sends true temperature values to the electronic package. Therefore, changing a sensor or a tape does not require a new calibration.

The unit complies with a host of regulations, including:

  • IMO (Solas 74, MARPOL 73/78)
  • ISO (4512, 3170, 4268)
  • API (MPMS Chap 3.1A, MPMS Chap 7, MPMS Chap 8.1, MPMS Chap 17.11)
  • IP (PMM Part III-1, PMM Part IV)
  • EC Directive 89/336/EEC (EMC)
  • EC Directive 94/9/EC (MED)
  • EC Directive 96/98/EC (ATEX 100a).

It has been approved by:

  • National authorities (USCG, MSA, GOST-R)
  • All major classification societies
  • ATEX, IECEx, Factory Mutual, NEPSI, GOST standard.

What Problems Does It Solve?

Honeywell’s HERMetic UTImeter Rtex allows static verification of the content in a tank and continuous temperature reading of the liquid with incomparable repeatability. The fully modular unit ensures high accuracy and stability, while reducing maintenance costs for users.
Chat With Us
WeCreativez WhatsApp Support
Our sales team is here to answer your questions. Ask us anything!
👋 Hi, Are you looking for Marine Equipments?