GEORIM ENGINEERING

HOME / PARTNERS/ GEORIM ENGINEERING

GEORIM ENGINEERING- AUTHORIZED SALES & SERVICE AGENT

 

*MEPC 285(70)* AMENDMENTS TO THE REVISED GUIDELINES AND SPECIFICATIONS FOR RESOLUTION MEPC.107(49)

AUTHORIZED SERVICE AGENCY FOR

  • Calibration, inspection, maintenance for the Georim Engg Korea 15ppm Bilge Alarm Monitor Model : GBA-155
  • 15PPM Bilge Separator (Oily Bilge Separator)
  • 15PPM Bilge Alarm (Oil Content Meter)
  • Coalescer filters
  • Bilge Pump (Piston Type)
  • Sludge Pump (Single Screw Type)


    15ppm Bilge Alarm (GBA-155)

    GBA-155 Complying to IMO MEPC 107(49) GBA-155 serves to continuously measure the concentration of oil in bilge and other waste water produced on a ship and produces alarm signal when oil concentration is 5 or 15 ppm

    SPECIFICATION

    ITEM DESCRIPTION
    Measuring Rang 0-30 ppm
    Measuring Accuracy 15ppm +/-5 ppm ( IMO Resolution MEPC 107(49)
    Set Point 15 ppm
    Response Time Time Delay :0 second (Below 5 sec)
    Alarm Contacts / Rating Normal / Alarm contacts
    Source of Electricity AC 100~ 220 V

    New Bilge Alarm Monitor Complete Set 15 PPM BILGE ALARM MONITOR P/N.: GBA-155 Includes 5 Years Factory Calibration Type Approval IMO MEPC 107(49)

    GBA-155 MONITORS

    Spare Measuring Cell / Sensing Module for GBA-155 Monitors. P/N.: GBA-502 Includes 5 Years Factory Calibration Type Approval IMO MEPC 107(49)

    Oil Content Meter Spares

    DESCRIPTION DRAWING NUMBER PART NUMBER
    Sample Tube BA-G-02 GBA-507
    Fuse BA-G-02 GBA-508
    O-Ring for Sample Tube BA-G-02 GBA-509
    O-Ring for the Cap BA-G-02 GBA-510
    Wrench BA-F-02 GBA-511
    Brush BA-G-02 GBA-512
    Display Board with Front Cover BA-G-02 GBA-501
    Sensing Module BA-G-02 GBA-502
    Main Board BA-G-02 GBA-503

    Oily Water Separators (GRS Type)

    Complying to IMO MEPC 107(49)

    MODEL CAPACITY
    GRS-10EB 1.0 m3/HR
    GRS-20EB 2.0 m3/HR
    GRS-25EB 2.5 m3/HR
    GRS-50 EB 5.0 m3/HR
    GRS-100EB 10.0 m3/HR

    Oily Water Separators (UST Type)

    Complying to MEPC 60(33) Regulations.

    MODEL CAPACITY
    GRS-02EB 0.2 m3/HR
    GRS-03EB 0.3 m3/HR
    GRS-05EB 0.5 m3/HR

    Oily Water Separator Spares

    DESCRIPTION DRAWING NUMBER PART NUMBERS
    Sheet Packing (P.S.U) SP-10BGPH-03 9
    Sheet Packing (E.T.U) SP-10BGPH-03 21
    Handhole Packing SP-10BGPH-03 22
    Coalescer Filter (P.S.U) SP-10BGPH-03 19
    Coalescer Filter (E.T.U) SP-10BGPH-03 20

    Oily Water Separators (POS Type)

    Complying to MEPC60(33) Regulations.

    • Coalescer Filters
    • Bilge Pump (Piston Type)
    • Sludge Pump (Single Screw Pump / monotype)
    • Hydrophore Unit (GRH Series)
    • Sewage Treatment Equipment

    Guidelines : *MEPC 107(49)*

    “4.2.11 The validity of calibration certificates should be checked at IOPP annual/intermediate/renewal surveys. The accuracy of 15 ppm bilge alarms is to be checked by calibration and testing of the equipment conducted by a manufacturer or persons authorized by the manufacturer and should be done at intervals not exceeding five years or within the term specified in the manufacturer’s instructions, whichever is shorter.

    Alternatively the unit may be replaced by a calibrated 15 ppm bilge alarm.
    The calibration certificate for the 15 ppm bilge alarm, certifying the date of the last calibration check, should be retained on board for inspection purposes.

    The accuracy checks can only be done by the manufactureror persons authorized by the manufacturer.” *MARPOL Annex I – Chap.2-Reg.10

    1. An International Oil Pollution Prevention Certificate shall be issued for a period specified by the Administration, which shall not exceed five years.

     

     